Technical Specifications
Item | Specification |
---|---|
Cabinet installation standards | Can be installed in a standard 19" 800 mm-deep cabinet. A Huawei 2.2 m-high N68E cabinet is used by default. |
Dimensions without packaging (H x W x D) [mm(in.)] | 1420 mm x 442 mm x 650 mm (55.91 in. x 17.40 in. x 25.59 in.) (Chassis main body) 1420 mm x 442 mm x 770 mm (55.91 in. x 17.40 in. x 30.31 in.) (Dimensions of the chassis body together with cable trays and front and back attachments) |
Chassis height [U] | 32 U |
Weight without packaging [kg(lb)] | 94.4 kg (208.15 lb) |
Weight without packaging (full configuration) [kg(lb)] | 279 kg (615.2 lb) |
Typical power consumption (with configuration) [W] | 6210 W (fully configured with BSUF-240s) |
Typical heat dissipation (with configuration) [BTU/hour] | 20147.9 BTU/hour (fully configured with BSUF-240s) |
MTBF [year] | 21.66 year |
MTTR [hour] | 0.5 hour |
Availability | 0.999998327 |
Power supply mode | DC built-in |
Maximum number of power chassis inputs | (1 channel/PEM)*8 PEM=8 channels |
Rated input voltage [V] | 鈥48 V/ 鈥60 V |
Input voltage range [V] | 鈥38.4 V to 鈥72 V |
Maximum input current [A] | 70 A/module (8 modules in total, 4+4 backup) |
Maximum input cable size [mm²] | 35 mm²/channel |
Front-end circuit breaker/fuse [A] | 70 A |
Noise at normal temperature (acoustic power) [dB(A)] | NEBS-compliance (< 78 dBA @ 27掳C (80.6掳F)) |
Number of slots | 22 |
Number of service board slots | 16 |
Switching capacity | 12.58 Tbit/s(BSUF-240) |
Redundant MPUs | 1:1 |
Redundant Switch fabrics | 3+1 |
Redundant power supply | 4+4 |
Redundant fans | 2 partitions 2 assemblies/partition, each partition in support for proper fan operation in case of a single fan failure for a short period at 40掳C (104掳F) |
Long-term operating temperature [掳C(掳F)] | 0掳C to 45掳C (32掳F to 113掳F) |
Short-term operating temperature [掳C(掳F)] | -5掳C to 55掳C (23掳F to 131掳F) |
Restriction on the operating temperature variation rate [掳C(掳F)] | 鈮 30掳C/hour (86掳F/hour) |
Storage temperature [掳C(掳F)] | -40掳C to 70掳C (-40掳F to 158掳F) |
Long-term operating relative humidity [RH] | 5% RH to 85% RH, non-condensing |
Short-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Storage relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating altitude [m(ft.)] | 鈮 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the device must decrease by 1掳C [1.8掳F] for every 220 m [721.78 ft.].) |
Storage altitude [m(ft.)] | < 5000 m (16404 ft.) |