HUAWEI_ME60-X3_ROUTER

Integrated DC Chassis Components(ME60-X3)
ME60-X3 Integrated AC Chassis Components, (Including Dual AC Power)

Technical Specifications

 Technical specifications of the ME0B0BKPD330
ItemSpecification
Cabinet installation standardsCan be installed in a standard 19" 800 mm-deep cabinet. A Huawei 2.2 m-high N68E cabinet is used by default.
Dimensions without packaging (H x W x D) [mm(in.)]175 mm x 442 mm x 650 mm (6.89 in. x 17.40 in. x 25.59 in.)
Chassis height [U]4 U
Weight without packaging [kg(lb)]15 kg (33.07 lb)
Weight without packaging (full configuration) [kg(lb)]42 kg (92.59 lb)
Typical power consumption (with configuration) [W]

800 W (fully configured with BSUF-51s)

920 W (fully configured with BSUF-120s)

1239 W (fully configured with BSUF-241s)

Typical heat dissipation (with configuration) [BTU/hour]

2595.5 BTU/hour (fully configured with BSUF-51s)

2984.9 BTU/hour (fully configured with BSUF-120s)

4019.8 BTU/hour (fully configured with BSUF-241s)

MTBF [year]34.76 year
MTTR [hour]0.5 hour
Availability0.999998358
Power supply modeDC built-in
Maximum number of power chassis inputs(1 channel/PEM)*2 PEM=2 channels
Rated input voltage [V]鈥48 V/ 鈥60 V
Input voltage range [V]鈥38.4 V to 鈥72 V
Maximum input current [A]42 A/single-module
Maximum input cable size [mm²]25 mm²
Front-end circuit breaker/fuse [A]50 A
Noise at normal temperature (acoustic power) [dB(A)]ETSI-compliance (<72dBA @ 23掳C (73.4掳F))
Number of slots5
Number of service board slots3
Switching capacity1.08 Tbit/s
Redundant MPUs1:1
Redundant power supply1+1
Redundant fansSupport for proper fan operation in case of a single fan failure for a short period at 40掳C (104掳F)
Long-term operating temperature [掳C(掳F)]0掳C to 45掳C (32掳F to 113掳F)
Short-term operating temperature [掳C(掳F)]-5掳C to 55掳C (23掳F to 131掳F)
Restriction on the operating temperature variation rate [掳C(掳F)]鈮 30掳C/hour (86掳F/hour)
Storage temperature [掳C(掳F)]-40掳C to 70掳C (-40掳F to 158掳F)
Long-term operating relative humidity [RH]5% RH to 85% RH, non-condensing
Short-term operating relative humidity [RH]5% RH to 95% RH, non-condensing
Storage relative humidity [RH]5% RH to 95% RH, non-condensing
Long-term operating altitude [m(ft.)]鈮 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the device must decrease by 1掳C [1.8掳F] for every 220 m [721.78 ft.].)
Storage altitude [m(ft.)]< 5000 m (16404 ft.)
 Technical specifications of the ME0B0BKPA331
ItemSpecification
Cabinet installation standardsCan be installed in a standard 19" 800 mm-deep cabinet. A Huawei 2.2 m-high N68E cabinet is used by default.
Dimensions without packaging (H x W x D) [mm(in.)]220 mm x 442 mm x 650 mm (8.66 in. x 17.40 in. x 25.59 in.)
Chassis height [U]5 U
Weight without packaging [kg(lb)]25 kg (55.12 lb)
Weight without packaging (full configuration) [kg(lb)]52 kg (114.64 lb)
Typical power consumption (with configuration) [W]

950 W (fully configured with BSUF-51s)

1070 W (fully configured with BSUF-120s)

1386 W (fully configured with BSUF-241s)

Typical heat dissipation (with configuration) [BTU/hour]

3082.2 BTU/hour (fully configured with BSUF-51s)

3471.5 BTU/hour (fully configured with BSUF-120s)

4496.8 BTU/hour (fully configured with BSUF-241s)

MTBF [year]34.76 year
MTTR [hour]0.5 hour
Availability0.999998358
Power supply modeAC built-in
Maximum number of power chassis inputs(1 channel/PEM)*2 PEM=2 channels
Rated input voltage [V]200 V to 240 V
Input voltage range [V]180 V to 264 V
Maximum input current [A]12A/single-module
Maximum input cable size [mm²]Standard C19 cable
Front-end circuit breaker/fuse [A]16 A
Noise at normal temperature (acoustic power) [dB(A)]ETSI-compliance (<72dBA @ 23掳C (73.4掳F))
Number of slots5
Number of service board slots3
Switching capacity1.08 Tbit/s
Redundant MPUs1:1
Redundant power supply1+1
Redundant fansSupport for proper fan operation in case of a single fan failure for a short period at 40掳C (104掳F)
Long-term operating temperature [掳C(掳F)]0掳C to 45掳C (32掳F to 113掳F)
Short-term operating temperature [掳C(掳F)]-5掳C to 55掳C (23掳F to 131掳F)
Restriction on the operating temperature variation rate [掳C(掳F)]鈮 30掳C/hour (86掳F/hour)
Storage temperature [掳C(掳F)]-40掳C to 70掳C (-40掳F to 158掳F)
Long-term operating relative humidity [RH]5% RH to 85% RH, non-condensing
Short-term operating relative humidity [RH]5% RH to 95% RH, non-condensing
Storage relative humidity [RH]5% RH to 95% RH, non-condensing
Long-term operating altitude [m(ft.)]鈮 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the device must decrease by 1掳C [1.8掳F] for every 220 m [721.78 ft.].)
Storage altitude [m(ft.)]< 5000 m (16404 ft.)