HUAWEI_ME60-X16_ROUTER
Name: ROUTER
Model: ME60-X16
Manufacturer: HUAWEI
Producing Area: CN
Simple Description: ME60-X16 Integrated Chassis Components (Including 8 DC Power)
Price: Inquire   hot sale

Technical Specifications




Technical specifications of the ME0B0BKP1630
ItemSpecification
Cabinet installation standardsCan be installed in a standard 19" 800 mm-deep cabinet. A Huawei 2.2 m-high N68E cabinet is used by default.
Dimensions without packaging (H x W x D) [mm(in.)]

1420 mm x 442 mm x 650 mm (55.91 in. x 17.40 in. x 25.59 in.) (Chassis main body)

1420 mm x 442 mm x 770 mm (55.91 in. x 17.40 in. x 30.31 in.) (Dimensions of the chassis body together with cable trays and front and back attachments)

Chassis height [U]32 U
Weight without packaging [kg(lb)]94.4 kg (208.15 lb)
Weight without packaging (full configuration) [kg(lb)]279 kg (615.2 lb)
Typical power consumption (with configuration) [W]6210 W (fully configured with BSUF-240s)
Typical heat dissipation (with configuration) [BTU/hour]20147.9 BTU/hour (fully configured with BSUF-240s)
MTBF [year]21.66 year
MTTR [hour]0.5 hour
Availability0.999998327
Power supply modeDC built-in
Maximum number of power chassis inputs(1 channel/PEM)*8 PEM=8 channels
Rated input voltage [V]–48 V/ –60 V
Input voltage range [V]–38.4 V to –72 V
Maximum input current [A]70 A/module (8 modules in total, 4+4 backup)
Maximum input cable size [mm²]35 mm²/channel
Front-end circuit breaker/fuse [A]70 A
Noise at normal temperature (acoustic power) [dB(A)]NEBS-compliance (< 78 dBA @ 27°C (80.6°F))
Number of slots22
Number of service board slots16
Switching capacity12.58 Tbit/s(BSUF-240)
Redundant MPUs1:1
Redundant Switch fabrics3+1
Redundant power supply4+4
Redundant fans

2 partitions

2 assemblies/partition, each partition in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F)

Long-term operating temperature [°C(°F)]0°C to 45°C (32°F to 113°F)
Short-term operating temperature [°C(°F)]-5°C to 55°C (23°F to 131°F)
Restriction on the operating temperature variation rate [°C(°F)]≤ 30°C/hour (86°F/hour)
Storage temperature [°C(°F)]-40°C to 70°C (-40°F to 158°F)
Long-term operating relative humidity [RH]5% RH to 85% RH, non-condensing
Short-term operating relative humidity [RH]5% RH to 95% RH, non-condensing
Storage relative humidity [RH]5% RH to 95% RH, non-condensing
Long-term operating altitude [m(ft.)]≤ 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the device must decrease by 1°C [1.8°F] for every 220 m [721.78 ft.].)
Storage altitude [m(ft.)]< 5000 m (16404 ft.)